With this batteryoperated device tester, you can even without mains voltage the basic test nonlike protective conductor resistance, insulation resistance and leakage current. Test instruments for measuring electrical safety of devices per vde 0701 0702, iec 62353 and iec 6097443 features stateoftheart, multichannel measuring technology for fast measured value acquisition. Measured values are acquired via 16 channels simultaneously, so that all measured values are available at the same time. Inspection after repair, modification of electrical appliances periodic inspection on electrical appliances.
The device under test is connected to the measuring instrument via the integrated test socket. Specializing in the manufacturing of power transformers rating up to. Dadurch durfen deutlich weniger verbraucher an einen rcd installiert werden. Indication meaning green led the measured value is better than the strictest limit value. Safety complying with din vde 0404 iec 61010en 61010 din vde 0411 iec 61557en 61557 din vde 04 measurement category cat ii250 v pollution degree 2 protection class ii. Testers per din vde 0701, 0702 and 0751 characteristic values 1 for testing in accordance with din vde 0751, device leakage current is determined by means of differential current measurement as part of the test sequence. Fircd test 250 v 500 v 30 ma rcd 3 phase onoff press 2 sec. You may do so in any reasonable manner, but not in any. Tester for din en 60204 and vde 01 dqs certified per din en iso 9001. Gossen metrawatt din vde 0701 operating instructions manual. Protective conductor resistance insulation resistance protective conductor current for safety class i devices contact current for safety class ii devices absence of voltage at exposed, conductive parts. For testing devices and cables in combination with din vde. We offer a complete range of expertise in the field of metrology. Unitest 0701 0702pcmultitester 8993 unitest software es control 0701 0702 without interface cable 1252 unitest software es control complete package.
Vde 0701 2 test device for the safety testing of threephase and alternating current consumers according to bgv a3 bgv a2 germanoccupational safety regulations. Mz70004 extralow voltage module, adjustable module 2 mhe, 400 mm wide. Reference to din vde standards power guides din vde 0271 pvcinsulated cables and sheathed power cables for rated voltages up to and including 3,66 7,2 kv din vde 0276 part 603 distribution cables of nominal voltages u 0 u 0,61 kv. Minitest master pro base testers per din vde 07010702.
Messung des erdungswiderstandes mit kompensationsverfahren nach behrend abgleichbedingung. Measuring instrument for testing mobile devices after repair or maintenance according to din vde 0701 part 1 240 and periodic testing according to din vde 0702. The device under test is connected to the test instruments test socket to this end. Insulation multimeters and installation testers the insulation multimeter benning it 101 and the installation testers benning it 105 it 115 it are intended for safety testing of lowvoltage. Gmc metratester 4 operating instructions manual pdf. All measurements stipulated according to din vde 0701 and din vde 0702 can be conducted. The device under test is con nected to the measuring instrument via the integrated test socket. Megger 1003066 test meter din vde 07010702, bgv a3, en. Testers per din vde 0701 0702 minitest master pro minitest base minitest 3p master features as from series issued in march 2007 convenient connection the test instrument is intended for testing and measuring repaired or modified devices. This standard is withdrawn and is replaced by the following. The quick connector safety jacks are wired in parallel to the test. The following are measured in accordance with the regulations. Test case for testing per din vde 0701 0702 at single and 3phase equipment. Shutdown within 100 ms as a result of differential current measurement.
View and download gossen metrawatt din vde 0701 operating instructions manual online. Seculife st and seculife st hv test instrument for din. Work devices mains operated electronic devices handheld electric tools extension cords household appliances data processing devices electrical medical devices arc welding units. The number and type of required measurements are determined according to the classification of the device under test. Mz70002 extralow voltage module module 2 mhe, 200 mm wide extralow voltage switchable 35812244248 v ac 100 va maskm 4804 item no. Metratester 4, 5, 5f and 5fe testers for din vde 0701 and 0702 334881703 53. Tester for din vde 0701 0702 features convenient connection the test instrument is intended for the testing and measurement of repaired or modified devices. Din vde 0701 0702 key functions earth bond voltage drop measurement insulation resistance measurement residual voltage measurement earth bond resistance measurement substitute leakage current measurement general information integrated memory for 1500 measurement values standard, builtin irrs232 interface for. Testers per din vde 07010702 minitest master pro minitest base minitest 3p master features as from series issued in march 2007 convenient connection the test instrument is intended for testing and measuring repaired or modified devices. Easy to perform various tests specified in din vde 07010702, capable of judging passfail of tests by led on the panel and by buzzer. With this device tester cones you to quickly and conveniently networkindependent tests according to din vde 0701 0702, bgv a3 dguv rule 3.
Convenient connection the test instrument is intended for the testing and measurement of repaired or modified devices. D bedienungsanleitung operating manual f notice demploi. Mit messprotokoll erstellen sie messprotokolle nach din vde 0100, 0701, 0702 bzw. M7010v031 n iec 62638 e vde 0701 0702 u testing of extension cables u passive test sequence device is not started up u active test sequence device is started up u testing of computer equipment n iec 62353 vde 0751, testing of electrical medical devices. Seculife st and seculife st hv test instrument for din en. Vde gs mark up to 20mm in height vde gs mark over 20mm in height technical working equipment and commodities ready for use, in the sense of prodsg optional for such products instead of vde mark according to vde eniec standards, other technical specifications as well as possible provisions of law with respect to safety and health. M6202 1test socket if the device under test hereinafter, referred as dut in this document is equipped with a mains plug, the measurement of protective conductor. Tester for din vde 0701 0702 dqs certified per din en iso 9001 reg. Din vde 0701 0702 i ec 6 2353 vde 0751 test instrument for bgv a3 and mpg universal test instrument for testing the electrical safety of electrical devices in accordance with occupational safety legislation, medical device regulations and bgv a3.
This file is licensed under the creative commons attribution 3. Our calibration laboratory is accredited in accordance with din en iso iec 17025. Highspeed spiral doors for deepfreeze applications tk series 02 tk series the cold chain for deepfrozen products must never be interrupted during storage and transport. Es wird empfohlen, rcds mit zeitverzogertem auslosen zu verwenden, um eine fehlauslosung aufgrund neuer verbrauchersituationen, z. Reversing switch mains din vde 0701 0702 test sockets for external safety tester masfm 3200 item no. Din vde 0701, and for periodic testing per din vde 0702. Din vde 0701 0702 inspection after repair, modification of electrical appliances periodic inspection on electrical appliances general requirements for electrical safety. Din vde 0700 0701 0702 and iec 62353 vde 07511 dakks calibration certificate as standard feature german accreditation body dk150800101 features. M7010v033 same as m7010v032, but instead of iec 62353 vde 0751. View and download gmc metratester 4 operating instructions manual online.